⚡ Sydney's Pump Specialists Since 1985
✉ info@sewerpumpservices.com.au · 📍 Based in the Sutherland Shire · Servicing Greater Sydney
📸 Real jobs, real photos

Recent work

Every photo here is from our own jobs around Sydney — no stock images, no staging. Pit replacements, new pumps, gas-tight lids, grease traps and the tidy-ups that stop small problems becoming floods.

All photos from our own jobs
Pump specialists since 1985
Restricted Electrical (Motors)
24/7 emergency response
Yowie Bay

Two undersized cutter pumps swapped for a single DAB grinder

This pit had two undersized 0.75kW cutter pumps working a pressurised main — more than they were ever built to shift — run through a dual-pump controller packed with contactors and switchgear that had become the weak point of the whole system. We simplified the lot: out came both cutter pumps and all the control gear they leaned on, and in went a single DAB FEKA VS grinder sized for the duty, with the old controls and contactors bypassed. Fewer parts to fail, and a pump that can actually move what's put through it.

Before Two undersized 0.75kW cutter pumps in a Yowie Bay pit on a pressurised main, with tangled cabling and a dual-pump controller before replacement
After The same Yowie Bay pit after replacement — a single DAB FEKA VS grinder pump neatly installed with the dual-pump controls bypassed
Sutherland Shire

Overgrown pit brought back to life

This pit had been left to the garden for years — vines over the valve, perished cabling coiled on a broken slab, and a pump well past its best underneath it all. We fitted a new pump, new isolation valve and pipework, ran fresh electrical, and finished it with a gas-tight lid so the smell stays where it belongs.

Before An overgrown sewer pump pit in the Sutherland Shire with a rusted valve and perished cabling before replacement
After The same Sutherland Shire pit after the visit — new pump, tidy electrical in conduit and a gas-tight lid fitted
Illawong

Old above-ground Mono swapped for a submersible Davey

An old Mono pump sitting above a crumbling pit, exposed to the weather and on its last legs. We replaced the pit, swapped the Mono for a submersible Davey, ran new electrical, and sealed it all under a gas-tight lid. The after shot has the manhole open so you can see what's underneath: new pipework, new check valve, new switch on the post — nothing left of the rust collection.

Before An old above-ground Mono pump on a deteriorated pit in Illawong, Sydney, before replacement
After The finished Illawong pit with the manhole open, showing the new discharge pipework, check valve and switch on the post behind
Chiswick

Dual pump system — Ultraflows changed to Daveys

A callout for a dual system with both Ultraflow pumps faulty, crammed into one corner of the pit with their old pipework. We replaced both pumps with Daveys, fitted new floats and fittings, and re-ran the pipework properly. The after photo says it: a clean pit, two new pumps, floats free to do their job.

Before Two faulty Ultraflow pumps and old pipework crammed in the corner of a Chiswick pit before replacement
After The same Chiswick pit from above after the visit, with two new Davey pumps, new floats and tidy pipework
Burraneer

Pit replacement — and moved to where it should have been

Sometimes the right fix isn't just a new pit, it's a new spot. This old pit sat brimming in the middle of a garden bed — waterlogged, sludged up, and in a location that made every service visit harder than it needed to be. We installed a new pit in a better position, fitted a new pump, ran new electrical and switchgear, and backfilled the old spot — you can see the same brick circle in both photos, first with a pit brimming in it, then with garden going back in.

Before An old waterlogged sewer pump pit brimming in the middle of a Burraneer garden bed before replacement and relocation
After The relocated Burraneer pump pit with new lid and switchgear by the fence, with the old pit's spot backfilled in the garden bed in front
Ryde

New house, rough pump setup made right

A brand-new house — and a pump pit that looked like the last trade out the gate. The pump itself was sound, but it had been dropped in with the cabling thrown loose, sitting exactly where it could foul the float, and more pump than this duty needed. We tidied the cabling, secured the float so it swings free, and left the system working the way a new home deserves.

Before A Saber pump in a new Ryde home's pit with loose tangled cabling left where it can obstruct the float
After The same Ryde pump pit after tidying — cabling secured and float reattached so it swings freely
Five Dock

Corroded dual-pump controller replaced with a new Kenrahn

The old dual-pump controller had rusted right through — housing, fixings and all — with the alarm and the pump changeover no longer to be trusted. We pulled it out, fitted a new Kenrahn panel sized to the system, wired in the floats, alarm and overload protection, and left it MAN-OFF-AUTO tested and clearly labelled. The pumps alternate again and the alarm does its job.

Before An old dual-pump controller at Five Dock, Sydney, rusted through and removed, with its DANGER label and isolator still attached
After The replacement Kenrahn dual-pump control panel at Five Dock, mounted and wired with the door open showing the schematic
Cronulla

New apartment garage, cables thrown in loose

A dual pump system under a new apartment building's garage, with the cabling left loose to drift into the floats — the classic fault-in-waiting. We tied everything back clear, checked both pumps and floats, and turned a flood risk into a system the building can rely on.

Before A dual pump pit under a Cronulla apartment garage as found, with loose cabling fouling the float switches
After The same Cronulla pit after the visit with cabling tied back clear of the floats
Sydney

Commercial grease trap pumps, caked solid

Grease trap duty is the hardest work a pump can do. These two came up caked in fat, with the rising mains coating up the same way on the inside. We cleaned and serviced both pumps, scraped the mains back to clear bore, and put it all back together — valves, camlocks and pipework ready for the next round. A grease trap never photographs pretty, but there's a difference between filthy and failing.

Before Two grease trap pumps lifted from a Sydney commercial pit, caked in fat buildup
After The Sydney grease trap pit with both pumps cleaned, reinstalled and reconnected to the valves and camlocks

Got a pit that looks like one of the "before" photos? That's exactly the work we do — repairs, pit installations and scheduled servicing across Sydney.

Want yours to be the next after photo?

Send us a photo of your pit or pump and tell us what it's doing. We'll give you a straight assessment and a clear price — same honest work you see on this page.

📞 Call 0415 210 267 — 24/7